  1. Dec 18, 2024

    Final - 30 minutes

    Compliant

    InspectorChris Andrejka

  2. Nov 27, 2024

    Geogrid

    Compliant

    InspectorChris Andrejka

    Wall D 3rd layer of geogrid appears to be installed per engineered plans.
  3. Nov 27, 2024

    Footing

    Compliant

    InspectorChris Andrejka

  4. Nov 27, 2024

    Setbacks

    Compliant

    InspectorChris Andrejka

  5. Nov 27, 2024

    Drain Tile

    Compliant

    InspectorChris Andrejka

  6. Nov 25, 2024

    Geogrid

    Non-Compliant

    InspectorChris Andrejka

    Wall D geogrid 3rd layer is short of the 5'6" required length per the engineered plans. this is due to the fact that in order to go back the two additional feet would require undermining large growth trees. I have notified the Engineer of this issue and requested additional plans.
  7. Nov 22, 2024

    Miscellaneous

    Compliant

    InspectorChris Andrejka

    Engineering acceptance letter received for all walls.
  8. Nov 12, 2024

    Drain Tile

    Partial Pass

    InspectorChris Pequin

    Wall D - Drain tile installed. No daylights installed yet. Approximately 40 feet of wall completed so far started from the road.
  9. Nov 12, 2024

    Footing

    Partial Pass

    InspectorChris Pequin

    Wall D - first 40 feet from road side
  10. Nov 12, 2024

    Geogrid

    Partial Pass

    InspectorChris Pequin

    Wall D - First 2 layers of geogrid installed. Need to see 3rd layer as wall continues upward toward the rear of the property.