PULLFIRST[THE RECORD]
Permit / Apple Valley← Search
#AV132253

Building

15977 Harmony Way, Apple Valley

IssuedJan 30, 2025
StatusUnknown
Value$15,000
Inspections3
Scope of work

Basement Finish, 108sf new-Add bedroom/bathroom in basement

Location context
Parcel014580108390
Coordinates44.71801, -93.23016
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$83.75
Total paid$83.75
Timeline
ApprovedJan 30, 2025
IssuedJan 30, 2025
ExpiresFeb 2, 2026
Inspection record
Inspections3
Passed0
Failed1
  1. Apr 29, 2025

    Final - 30 minutes

    Fail

    InspectorChris Andrejka

    missing smoke detector and co detector outside of basement bedroom. handrail must be continuous for entire flight of stairs. handrail must be within 34"-38" when measured from nose of stair (handrail is currently measuring 44" at bottom of stairs).
  2. Mar 27, 2025

    Final - 30 minutes

    Non-Compliant

    InspectorChris Andrejka

    basement bedroom missing smoke detector. stairs missing continuous handrail that terminates to the wall at the top and bottom of the stairs. The nosing at the top of the stairs was installed sticking up. risers in a flight of stairs must be within 3/8" of each other with a maximum rise of 7 3/4".
  3. Feb 12, 2025

    Framing - 30 minutes

    Compliant

    InspectorChris Andrejka

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.