Permit / Apple Valley← Search
#AV131982Building
13073 Diamond Path, Apple Valley
IssuedMar 17, 2025
StatusUnknown
Value$1,200,000
Inspections16
Scope of work
Dwelling, First flr 1903 SF, Second flr 1877 SF, LL 1531 SF, Garage 1035 SF, Front porch 85 SF.
Location context
Parcel014430001030
Coordinates44.76039, -93.16078
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$2,078.13
Total paid$2,078.13
Timeline
ApprovedMar 17, 2025
IssuedMar 17, 2025
Inspection record
Inspections16
Passed4
Failed0
- Oct 14, 2025
Final - 30 minutes
CompliantInspectorPatrick Devery
New survey reviewed showing retaining wall at rear of property- measured and not in filtration basin.
- Sep 23, 2025
Framing - Basement
Not Applicable/RequiredInspectorChris Pequin
- Aug 26, 2025
Lath
CompliantInspectorPatrick Devery
Second level area at north wall of front entrance.
- Aug 18, 2025
Lath
Partial PassInspectorPatrick Devery
East side of house at second level above garage.
- Aug 5, 2025
Lath
Partial PassInspectorPatrick Devery
North face of west side of house (opposite face of deck).
- Jul 30, 2025
Lath
Partial PassInspectorCraig Schultz
grade d paper in place, self furring lath in place, weep screed is in place, will be calling for other areas on house chimney and room in attic wall above garage overhead doors
- Jun 18, 2025
Insulation
CompliantInspectorChris Pequin
- Jun 10, 2025
Framing - 60 minutes
CompliantInspectorChris Pequin
- Jun 9, 2025
Framing - 60 minutes
Non-CompliantInspectorChris Pequin
In floor heat air test must pass to approve. Deck currently temped and 6X6s not installed yet. Verified all exterior braced walls. In basement a few areas were missing anchor bolts. The blocking between C02 and its piggybacks do not match engineers cut sheets.
- May 30, 2025
Footing
CompliantInspectorChris Pequin
2, 24 inch sonotubes for deck 42 inches deep
- Apr 29, 2025
Footing
CompliantInspectorChris Pequin
Revised engineering provided for elevator pit and horizontal #4 bar added as per plans. Verified radon vapor barrier seals while on site.
- Apr 23, 2025
Footing
Non-CompliantInspectorChris Andrejka
elevator pad does not match engineered plans. the plans called for two rows of #4 bar (6"oc top, 4"oc bottom) the thickness of the pad does not allow the addition of a second grid of rebar. updated engineering will need to be submitted for review and approval through projectdox.
- Apr 7, 2025
Foundation/Water Proofing
CompliantInspectorPatrick Devery
- Apr 3, 2025
As Built
CompliantInspectorEvan Acosta
- Apr 1, 2025
Poured Wall
CompliantInspectorChris Pequin
Forms in place. Width and reinforcement matching plan page S1 for foundation engineering from Oswell.
- Mar 27, 2025
Footing
Partial PassInspectorChris Pequin
20 inch forms throughout with pad locations matching plans. Missing midspan footing for deck. Need to inspect elevator pad reinforcement prior to covering. Need as built to engineering (evan.acosta@applevalleymn.gov)
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.