PULLFIRST[THE RECORD]
Permit / Apple Valley← Search
#AV134111

Plumbing

15460 English Ave, Apple Valley

IssuedJul 1, 2025
StatusUnknown
Value$89,500
Inspections11
Scope of work

Fixtures, install sanitary waste, grease waste, roof draions, and water meters for base building

Location context
Parcel014787001020
Coordinates44.72026, -93.17888
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$388.25
Total paid$388.25
Timeline
ApprovedJun 17, 2025
IssuedJul 1, 2025
Inspection record
Inspections11
Passed4
Failed0
  1. Nov 19, 2025

    Backflow Test Report Received

    Compliant

    InspectorChris Pequin

  2. Nov 19, 2025

    Final

    Compliant

    InspectorChris Pequin

  3. Nov 12, 2025

    Final

    Non-Compliant

    InspectorChris Pequin

    (roof only) need install manual for water heater. Boot on VTR not removed.
  4. Nov 12, 2025

    Backflow Test Report Received

    Partial Pass

    InspectorChris Pequin

    Backflow test report received for pop machine only. Still need BF test reports for fire suppression and irrigation.
  5. Oct 30, 2025

    Final

    Non-Compliant

    InspectorChris Pequin

    Need 3 backflow test reports (FS, irrigation, and soda station). Mop sinks must be sealed at base. Chemical dispensers at sink must be installed to verify protection. Manometer passes and tested GI as well.
  6. Sep 25, 2025

    Rough In

    Compliant

    InspectorChris Pequin

  7. Sep 12, 2025

    Air Test

    Compliant

    InspectorChris Pequin

    5# on DWV at rough in and 40# on gas piping
  8. Sep 12, 2025

    Rough In

    Partial Pass

    InspectorChris Pequin

    All rough ins matching DLI approved plans. Need to see final VTR connection.
  9. Aug 8, 2025

    Underground

    Compliant

    InspectorChris Pequin

    GW, Storm, and San all air tested at 5# for 30 mins (no # drop). Matches plans.
  10. Aug 5, 2025

    Underground

    Partial Pass

    InspectorChris Pequin

    E to W mains for GW, San and storm. Wyed but not ran from mains.
  11. Aug 1, 2025

    Underground

    Partial Pass

    InspectorChris Pequin

    N to S 4 inch San and 6 inch storm. All storm inspected (no air) for entire underground. Air test to be performed on entire DWV.