Permit / Apple Valley← Search
#AV132779Building
15460 English Ave, Apple Valley
IssuedJul 10, 2025
StatusUnknown
Value$2,500,000
Inspections24
Scope of work
Restaurant
Location context
Parcel014787001020
Coordinates44.72026, -93.17888
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$3,000
Total paid$3,000
Timeline
ApprovedJul 10, 2025
IssuedJul 10, 2025
Inspection record
Inspections24
Passed5
Failed0
- Nov 20, 2025
Ice & Water
CompliantInspectorChris Pequin
- Nov 20, 2025
Final - 60 minutes
CompliantInspectorChris Pequin
- Nov 17, 2025
Ice & Water
Non-CompliantInspectorChris Pequin
Missing flashing for roof to exterior walls
- Nov 17, 2025
Final - 60 minutes
Non-CompliantInspectorChris Pequin
Front of house inspection of dining and parking area and bathrooms is compliant. Corrections are as follows: -Need to inspect kitchen area -MDH approval needed -Need 2 backflows still -Flashing on roof -Guard on roof -Fire alarm permit open -HVAC open -Plumbing open -3 downspouts are draining onto the sidewalk. Roofs are not permitted to drain onto sidewalks.
- Nov 13, 2025
Special Inspection
CompliantInspectorChris Pequin
Grease maintenance form received
- Nov 12, 2025
Ice & Water
Non-CompliantInspectorChris Pequin
Rooftop guard for ships ladder not secured
- Oct 30, 2025
Special Inspection
CompliantInspectorChris Pequin
Final SI report received
- Sep 29, 2025
Framing - 60 minutes
CompliantInspectorChris Pequin
- Sep 29, 2025
Insulation
CompliantInspectorChris Pequin
- Sep 29, 2025
Wrap Inspection
CompliantInspectorChris Pequin
- Sep 29, 2025
As Built
Not Applicable/RequiredInspectorChris Pequin
- Sep 25, 2025
Framing - 60 minutes
Non-CompliantInspectorChris Pequin
Cannot pass until electrical rough in passes
- Sep 25, 2025
Insulation
Non-CompliantInspectorChris Pequin
Vapor barrier not sealed. HW insulated.
- Sep 23, 2025
Poured Wall
CompliantInspectorChris Pequin
- Sep 23, 2025
Framing - 60 minutes
Non-CompliantInspectorChris Pequin
Missing ledger struts for RTU (det 8 on S3.2)
- Sep 23, 2025
Insulation
Partial PassInspectorChris Pequin
Batt/poly behind electrical wall
- Sep 9, 2025
Framing - 60 minutes
Partial PassInspectorChris Pequin
All exterior sheathing, nail patterns, and shear walls
- Sep 8, 2025
Framing - 60 minutes
Non-CompliantInspectorChris Pequin
(exterior inspection). Hold down location fixed as to not utilize jack stud from door. Nailing pattern on exterior sheathing is incorrect. Must be 6 inches on panel edges.
- Sep 2, 2025
Framing - 60 minutes
Non-CompliantInspectorChris Pequin
Shear wall C uses a jack as contributing to the double stud. Either move hold down 8 inches max from end and double continuous stud or get determination from engineer it is OK. Exterior shear wall nail patterns exceed 6 inches in numerous locations. Roof parapets compliant.
- Aug 11, 2025
Foundation/Water Proofing
CompliantInspectorChris Pequin
Vapor barrier prior to slab
- Aug 11, 2025
Insulation
Partial PassInspectorChris Pequin
Freezer floor
- Jul 25, 2025
Footing
CompliantInspectorChris Pequin
Trash corral
- Jul 25, 2025
Poured Wall
Partial PassInspectorChris Pequin
Foundation restaurant walls per plan
- Jul 23, 2025
Footing
Partial PassInspectorChris Pequin
All exterior footings/pads match approved plans