PULLFIRST[THE RECORD]
Permit / Apple Valley← Search
#AV136485

Building

14465 Holland Ct, Apple Valley

IssuedAug 13, 2025
StatusUnknown
Value$45,000
Inspections7
Scope of work

Miscellaneous, 0 SF New - Pella Sunroom Kit to be removed and replaced with 3 unit window and 3 skylights

Location context
Parcel012750201190
Coordinates44.74006, -93.24091
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$194.5
Total paid$194.5
Timeline
ApprovedAug 12, 2025
IssuedAug 13, 2025
Inspection record
Inspections7
Passed2
Failed0
  1. Oct 22, 2025

    Final - 30 minutes

    Compliant

    InspectorPatrick Devery

    Etching on bathroom windows found in upper right corner. Smoke and C.O. alarms added.
  2. Oct 15, 2025

    Final - 30 minutes

    Non-Compliant

    InspectorChris Andrejka

    windows adjacent to tub needs to be tempered. missing smoke detectors in bedrooms. missing co detector within 10' of bedrooms.
  3. Sep 19, 2025

    Insulation

    Pass

    InspectorCraig Schultz

    correction is made
  4. Sep 17, 2025

    Insulation

    Non-Compliant

    InspectorChris Pequin

    Current insulation has batts placed over framing instead of inside stud cavities and vapor barriers are not sealed at edges and seams.
  5. Sep 12, 2025

    Framing - 30 minutes

    Pass

    InspectorCraig Schultz

    corrections are made
  6. Sep 3, 2025

    Framing - 30 minutes

    Non-Compliant

    InspectorCraig Schultz

    1. resubmit plan with the correct hangers being used at the top beam between the girder trusses. 2. hangers are not installed properly-overlapping, not enough nails. 3. add something for rotation at the outside of top plate at the cripple studs - include on the resubmitted plan. 4. aren't any hangers where shown on the 2x4 cross members at the top and bottom of the skylight framing. before reinspecting make sure the resubmitted plan is approved by plan reviewer.
  7. Sep 2, 2025

    Framing - 30 minutes

    Not Ready

    InspectorPatrick Devery

    Revised plans have been submitted and are currently in review. Approved plans needed for framing inspection to pass.

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.