Permit / Apple Valley← Search
#AV138538

Building

13415 Gull Ct, Apple Valley

IssuedOct 27, 2025
StatusUnknown
Value$40,000
Inspections3
Scope of work

Basement Finish, Complete basment finish, add one egress window and basement bathroom rough in, 1050 SF.

Location context
Parcel017595003100
Coordinates44.75476, -93.22535
Loading map…
200 nearby
This permitNearby
Fees & payments
Total fees$177.75
Total paid$177.75
Timeline
ApprovedOct 27, 2025
IssuedOct 27, 2025
Inspection record
Inspections3
Passed0
Failed0
  1. Dec 30, 2025

    Insulation

    Compliant

    InspectorPatrick Devery

  2. Dec 24, 2025

    Framing - 30 minutes

    Compliant

    InspectorPatrick Devery

  3. Dec 11, 2025

    Framing - 30 minutes

    Non-Compliant

    InspectorPatrick Devery

    A separate mechanical permit is required for alterations. A header is required at bearing wall into new sleeping room. Kraft faced insulation no allowed over existing vapor barrier at CMU walls. Draftstopping required at soffit on interior of sleeping room wall.