PULLFIRST[THE RECORD]
Permit / Apple Valley← Search
#AV139161

Building

7169 153rd St W, Apple Valley

IssuedFeb 5, 2026
StatusUnknown
Value$400,000
Inspections26
Scope of work

Footings/Foundation

Location context
Parcel018175003020
Coordinates44.72715, -93.21104
Loading map…
199 nearby
This permitNearby
Fees & payments
Total fees$880.63
Total paid$880.63
Timeline
ApprovedFeb 4, 2026
IssuedFeb 5, 2026
Inspection record
Inspections26
Passed15
Failed0
  1. Mar 3, 2026

    Footing

    Compliant

    InspectorChris Pequin

  2. Mar 3, 2026

    Foundation/Water Proofing

    Partial Pass

    InspectorChris Pequin

    Last remaining piers as per plan. Work is now finished for footing and foundation permit however it is to remain open until concrete testing acceptance is provided by Chosen Valley Testing.
  3. Mar 2, 2026

    Foundation/Water Proofing

    Partial Pass

    InspectorChris Pequin

    All column piers except the 4 interior pads
  4. Mar 2, 2026

    Footing

    Partial Pass

    InspectorChris Pequin

    Interior footings 2-F4s and 2-F5s
  5. Feb 27, 2026

    Footing

    Partial Pass

    InspectorChris Pequin

    Pad footings at the following gridlines: D3, D.6-3, E.7-6, F.2-6, F.7-6, G.5-6, F.2-5, F.7-5, G.3-5, H.1-5, L-6.4
  6. Feb 27, 2026·1:00 PM - 1:30 PM

    Footing

    scheduled

    InspectorChris Pequin

  7. Feb 26, 2026·1:00 PM - 1:30 PM

    Footing

    scheduled

    InspectorChris Pequin

  8. Feb 26, 2026

    Foundation/Water Proofing

    Partial Pass

    InspectorChris Pequin

    Last remaining forms for exterior poured wall complete (and strip footing through center for interior LB precast)
  9. Feb 26, 2026

    Footing

    Partial Pass

    InspectorChris Pequin

    Pad footings inside elevator pit and 3 adjacent pad footings to East
  10. Feb 25, 2026·1:00 PM - 1:30 PM

    Footing

    scheduled

    InspectorChris Pequin

  11. Feb 24, 2026

    Footing

    Partial Pass

    InspectorChris Pequin

    Last remaining strip footings except for trash enclosure. Still need to inspect interior pads.
  12. Feb 24, 2026·1:00 PM - 1:30 PM

    Footing

    scheduled

    InspectorChris Pequin

  13. Feb 23, 2026·1:00 PM - 1:30 PM

    Footing

    scheduled

    InspectorChris Pequin

  14. Feb 23, 2026

    Foundation/Water Proofing

    Partial Pass

    InspectorChris Pequin

    Poured wall A1-A2
  15. Feb 20, 2026

    Foundation/Water Proofing

    Partial Pass

    InspectorChris Pequin

    4 of 5 C2 piers on SW corner. Forms and reinforcement from gridlines: E4-K4, K4-K8, K8-E8
  16. Feb 20, 2026·1:00 PM - 1:30 PM

    Footing

    scheduled

    InspectorChris Pequin

  17. Feb 20, 2026

    Footing

    Partial Pass

    InspectorChris Pequin

    Footing aside from trash enclosure footing from gridline: A1-A2
  18. Feb 19, 2026·1:00 PM - 1:30 PM

    Footing

    scheduled

    InspectorChris Pequin

  19. Feb 18, 2026

    Foundation/Water Proofing

    Partial Pass

    InspectorChris Pequin

    Waterproofing membrane and rigid foam from A1-M3
  20. Feb 18, 2026

    Footing

    Partial Pass

    InspectorChris Pequin

    Interior precast footing at 2' and 2'-5" from gridline :D4-K4
  21. Feb 18, 2026·2:00 PM - 2:30 PM

    Footing

    scheduled

    InspectorChris Pequin

  22. Feb 17, 2026

    Footing

    Partial Pass

    InspectorChris Pequin

    24"X12" continuous footings with 2 #5 from gridline M3-E8
  23. Feb 17, 2026·1:00 PM - 1:30 PM

    Footing

    scheduled

    InspectorChris Pequin

  24. Feb 17, 2026

    Foundation/Water Proofing

    Partial Pass

    InspectorChris Pequin

    A1-M3 12 inch poured wall with 2 EF horiz and vert at 16 OC. Need updated structural plans with reinforcement (plan on site only not in Pdox).
  25. Feb 13, 2026

    Footing

    Partial Pass

    InspectorChris Pequin

    24"X12" continuous footings with 2 #5 from gridline A1-M3
Show 1 earlier inspection
  1. Feb 13, 2026·2:00 PM - 3:00 PM

    Footing

    scheduled

    InspectorChris Pequin

Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.