7068 MORRIS THOMAS ROAD, SAGINAW, MN 55779
Standard 19260021 B02
Standard 19260020 B01
Standard 19260550 A15 I
ELECTRIC SHOCK - CONTACT WITH OVERHEAD LINE THRU BOOM
AN EMPLOYEE WAS UNLOADING CONCRETE BLOCKS AT A CONSTRUCTION SITE. HE WAS OPERATI NG THE BOOM ON HIS TRUCK BY MEANS OF A REMOTE CONTROL WHILE HE WAS STANDING ON T HE GROUND. THE TRUCK WAS PARKED NEAR AN OVERHEAD POWER LINE, WHICH WAS LOCATED 1 8.75 FEET AWAY (CENTERLINE TO CENTERLINE). THE TRUCK WAS EQUIPPED WITH AN OHIO C RANE WITH A 22-FOOT-LONG BOOM. THE EMPLOYEE ROTATED AND RAISED THE BOOM UNTIL IT WAS 12.5 FEET ABOVE THE GROUND, THEN HE LOWERED IT INTO THE POWER LINE. THE EMP LOYEE WAS ELECTROCUTED.
Data sourced from Minnesota Department of Labor & Industry, Minnesota Attorney General, federal OSHA, and municipal permit offices. Records are public and may not reflect pending appeals or corrections.